Description
Air Source Heat Pump – Air To Water AquaThermica for Domestic Hot Water
The TESY AquaThermica is a wall hung Compact Air Source Heat Pump for generating hot water for domestic hot water. The TESY COMPACT AquaThermica incorporates a built in air source heat pump and 100 litre hot water cylnder to offer one compact appliance that is designed to be installed in your property. It has a capacity of 100 litres of water and offers a maximum water temperature of 60 degrees. The appliance has an efficiency rating of A+ making it one of the most efficient water heaters in its class. It is powered by a single phase 230v power supply that is wired via a fused spur.
The heat pump requires connection of 125mm diameter intake and exhaust air hoses, that connect to the top of the appliance.
The Compact AquaThermica offers a state-of-the-art, compact solution to creating energy efficient hot water for domestic hot water. It is an environmentally friendly product, o
perating with renewable energy sources resulting in lower CO2 emissions. The appliance is highly efficient with a precisely balanced refrigerant cycle due to an electronically commutated motor and an electronic expansion valve resulting in 75% lower electricity consumption when compared to similar sized electric hot water cylinders.
The appliance includes a user friendly programmable LCD touch control screen and a built in diagnostics control system.
Exhaust and Intake Hoses Not Included – 125mm diameter.
IMPORTANT: This appliance must be installed in accordance with G3 un-vented hot water regulations and requires 2 forms of safety device to be installed on the hot side of the pipework. We recommend installing an 8 litre safety expansion vessel £34.99 and a 3.5 bar pressure release valve £14.99. If you have any technical questions prior to buying on eBay please call 0161 439 1400.
Specification
Maximum working pressure | 8 bar |
Energy class | A+ |
Diameter | 520 mm |
Maximum operational temperature |
60 °C |
Capacity | 100 L |
Thermo pocket | x1 pieces |
Heating time | 7:04 h:min |
Declared load profile | M |
Insulation (rigid PU) | 50 mm |
Electric heating element power | 1.5 kW |
HP maximum absorption | 0.663 + 1.5 (e-heater) = 2.163 kW |
Min. ÷ max temperature heat pump air intake (90% R.H.) | -5 ÷ 43 °C |
Frequency | 50 Hz |
Annual electricity consumption in kWh under average climate conditions | 1237.7 kWh |
Power supply | 230 V |
Compressor | Rotary |
Min. ÷ max temperature installation site | -10 ÷ 43 °C |
Compressor protection | Thermal circuit breaker with automatic reset |
Refrigernt Charge | 760 g |
Thermodynamic circuit protection type | Safety pressure switch with automatic reset |
CO2 Equivalent | 0.480 |
Fan | Centrifugal |
HP Maximum settable temperature | 60 °C |
Internal protection | Single safety thermostat with manual reset on a resistive element |
Refrigerant | R513 a |
Max. pressure head available | 50 Pa |
Motor protection | Internal thermal circuit breaker with automatic reset |
Condenser | Wrapped externally not in contact with water |
Transport weight | 110 kg |
Sound power Lw (A) | 53 dB(A) |
Automatic anti-Legionnella disinfection cycle | YES |
Height | 1351 mm |
Minimum height of the premise | 220 mm from ceiling |
Cathodic protection | Mg anode Ø 32 x 400 mm |
Defrosting | 4-way valve |
CoP (DHW) | 2.8 |
Heat Pump Thermal Power yield (P rated) | 1.2 kW |
Maximum legnth of pipe | 4 meters |
This item must be installed by a qualified installer.